Axial flow pump 2011-11-17
An axial flow pump, or AFP, is a common type of pump that essentially consists of a propeller in a pipe.
Magdrive Chemical Pumps Resist Corrosives 2011-11-16
Available through MICHAEL SMITH ENGINEERS, the Ultrachem pump series consists of three models which deliver flows up to a maximum of 59m3 /hour at heads up to 67 metres.
Tube pumps 2011-11-15
Lower pressure peristaltic pumps typically have dry casings and use rollers along with non-reinforced, extruded tubing.
Good practice is a minimum 0.3 of inlet diameter 2011-09-23
Good practice is a minimum 0.3 of inlet diameter from the sump floor to the inlet of the pump, if more than this it is ok. Question, how do you know it is cavitating?It seems unlikely that pumps of th
The spindle/plunger 2011-09-20
Spindle/ plunger: The spindle/plunger also known as valve stem has a valve attached at the bottom and the spring acts on top of it. The force exerted by spring is transferred to the valve through sp
Chemical requirements and atmospheric isolation pipe 2011-09-19
Water seal valve for working pressure 1.6 ~ 10.0MPa, work temperature 0 ~ 425
Aluminum-Bronze Vs. 316 Stainless Steel 2011-09-05
I will be pumping 3 different fluids, portable water, 1-10% Sodium Chloride brine and 1% Sodium Carbonate Alkaline (pH ~ 11) fluids. What material is best to use for the pump Aluminum-Bronze or 316 St
The other to check for shaft paraellness 2011-09-02
GREETINGS: I vote for the dial indicator(S)... ALSO be sure the pump base is grouted in place, the piping does not pull the pump out of allignment, and recheck after a day or two... I have been known